Search results for "Oxygen Radioisotopes"
showing 4 items of 4 documents
Central activation by histamine-induced itch: analogies to pain processing: a correlational analysis of O-15 H2O positron emission tomography studies
2001
The aim of this study was to identify the functional cerebral network involved in the central processing of itch and to detect analogies and differences to previously identified cerebral activation patterns triggered by painful noxious stimuli. Repeated positron emission tomography regional cerebral blood flow (rCBF) measurements using O15-labeled water were performed in six healthy right-handed male subjects (mean age 32 +/- 2 years). Each subject underwent 12 sequential rCBF measurements. In all subjects a standardized skin prick test was performed on the right forearm 2 min before each rCBF measurement. For activation, histamine was applied in nine tests in logarithmically increasing con…
The association between muscle EMG and perfusion in knee extensor muscles
2006
The relationships between electromyographic (EMG) activity and force as well as muscle blood flow and work have been well established. However, the association between muscle blood flow and EMG activity remains unsolved. Thus, to test the hypothesis that muscle EMG activity relates to muscle perfusion in different compartments of the quadriceps femoris (QF) muscle, 12 healthy male subjects were studied. During two very submaximal exercise bouts, at different exercise intensities, oxygen labelled radiowater and positron emission tomography were used to measure muscle perfusion. In addition, produced force of knee extensors and muscle EMG activity in the vastus lateralis (VL), vastus medialis…
Quantification of pulmonary blood flow (PBF): validation of perfusion MRI and nonlinear contrast agent (CA) dose correction with H(2)15O positron emi…
2009
Validation of quantification of pulmonary blood flow (PBF) with dynamic, contrast-enhanced MRI is still missing. A possible reason certainly lies in difficulties based on the nonlinear dependence of signal intensity (SI) from contrast agent (CA) concentration. Both aspects were addressed in this study. Nine healthy pigs were examined by first-pass perfusion MRI using gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and HO positron emission tomography (PET) imaging. Calculations of hemodynamic parameters were based on a one-compartment model (MR) and a two-compartment model (PET). Simulations showed a significant error when assuming a linear relation between MR SI and CA dose in the …
Mechanism of the Oxidation of Sulfides by Dioxiranes. 1. Intermediacy of a 10-S-4 Hypervalent Sulfur Adduct
2002
Earlier studies established that dimethyldioxirane (1a) reacts with sulfides 2 in two consecutive concerted electrophilic oxygen-transfer steps to give first sulfoxides 3 and then sulfones 4. The same sequential electrophilic oxidation model was assumed for the reaction of sulfides 2 with the strongly electrophilic methyl(trifluoromethyl)dioxirane (1b). In this paper we report on a systematic and general study on the mechanism of the reaction of simple sulfides 2 with DMDO (1a) and TFDO (1b) which provides clear evidence for the involvement of hypervalent sulfur species in the oxidation process. In the oxidation of sulfides 2a-c, diphenyl sulfide (2d), para-substituted aryl methyl sulfides …